Author: admin

  • uPVC vs Aluminium: Which Window Profile for Export?

    uPVC vs Aluminium: Which Window Profile for Export?

    uPVC vs Aluminium: Which Window Profile for Export?

    GLOBHAUS R&D · 8 min read · 2026-10-10

    uPVC vs Aluminium: Which Window Profile for Export?

    The window frame material debate usually stops at “PVC or aluminium?”. GLOBHAUS’s multi-chamber uPVC (UPVC) system profile is the right default for most export projects — here is why, in plain terms.

    What uPVC (UPVC) actually is

    It is a multi-chamber PVC-U profile with integrated steel reinforcement inside the chamber walls, then finished with a wood-grain interior film and a weather-stable white (or coloured) exterior. The steel gives rigidity; the uPVC gives insulation and a warm touch.

    vs pure PVC-U

    Standard PVC-U frames can be flexible over large spans and can creep under heat. The internal steel stiffens the profile so we can build bigger, quieter units without thickening the frame. Dimensional stability also keeps seals tight for longer.

    vs aluminium

    Aluminium is strong and slim, but it is a thermal bridge: without an expensive polyamide break, it sweats and leaks heat. Steel-reinforced uPVC matches most of aluminium’s rigidity while staying warm, and costs roughly 40% less.

    PropertyuPVC (steel-reinforced)AluminiumPure PVC-U
    Thermal (Uf)LowHigh (unless broken)Low
    RigidityHighVery highMedium
    Relative cost1.0×~1.6×~0.9×
    FormaldehydeNoneNoneNone

    Where it wins

    • Cold climates needing low U-values without aluminium pricing.
    • Projects wanting a warm wood-grain interior without real timber maintenance.
    • Large fixed and tilt-turn units where pure PVC would sag.
    Steel-reinforced uPVC is not a compromise. For 80% of residential and light-commercial exports, it is the optimum point on the cost-performance curve.

    The honest limits

    For ultra-slim curtain walls or spans beyond uPVC limits, aluminium still leads. We offer aluminium-clad uPVC systems exactly for those edge cases.

    Where each material fits

    uPVC (documented as vinyl windows in North American tenders) wins on thermal comfort and first cost for most residential and light-commercial openings, while aluminium wins on span, slim sightlines and curtain-wall scale. The honest way to choose is by aperture: small to medium windows and doors almost always favour uPVC on lifetime cost; very large lights, shopfronts and structural glazing favour aluminium. Hybrid aluminium-clad uPVC captures most of both — the warm multi-chamber core inside, a slim metal skin outside — at a mid price. The right answer is rarely 'one material for everything'; it is a per-opening decision based on size, colour requirement and the energy target.

    Thermal, cost and durability trade-offs

    A multi-chamber uPVC profile is intrinsically a better insulator than a metal frame of the same width, so matching the aluminium's U-value usually needs a thermal break and sometimes a wider frame. Aluminium's strength lets it hold larger panes with thinner frames, which clients value for views and for matching a building's metal language. Maintenance is similar in practice — both need occasional cleaning and gasket checks — but aluminium resists surface denting better while uPVC can discolour under sustained direct sun unless a UV-stable formulation is specified. Specific U-values, frame widths and finishes are confirmed per project against the quoted system and the local climate.

    Specifying without bias

    Write the specification around performance first: target U-value, acoustic rating, maximum pane size and colour, then let the factory propose the material that meets it at the right cost. Avoid locking the material early, because it pushes the quote in one direction before the performance need is clear. For mixed projects, allow uPVC on the standard openings and aluminium on the hero glazing — the building reads as one system when the colours and sightlines are coordinated. Request the comparison as two quoted options on the same performance baseline so the decision is financial, not tribal.

    Quick takeaways for specifiers

    The honest way to choose is by aperture and performance, not by loyalty to a material. Small to medium openings almost always favour uPVC on lifetime cost, while very large lights, shopfronts and structural glazing favour aluminium for its strength and slim sightlines. Aluminium-clad uPVC captures most of both benefits at a mid price when both warmth and a metal skin matter. Write the specification around the target U-value, acoustic rating, maximum pane size and colour first, then let the factory propose the material that meets it at the right cost. Requesting two quoted options on the same performance baseline turns the decision from tribal into financial, and usually reveals savings worth keeping. Where a façade mixes the two materials, set one colour and one sightline rule so the result reads as deliberate rather than as two systems bolted together by accident.

    GLOBHAUS · VIDEO

    Factory & Product Videos

    A new video from our Foshan factory, updated daily.

    #doorsandwindowsfactory #windowmanufacturer #customwindows #aluminumwindows #windowsanddoors · 2026-11-17

    See all videos on our YouTube channel →

  • Passive House Windows: What PHI Certification Means for Your Specification

    Passive House Windows: What PHI Certification Means for Your Specification

    Passive House Windows: What PHI Certification Means for Your Specification

    GLOBHAUS Certification Office · 6 min read · 2026-10-15

    Passive House Windows: What PHI Certification Means for Your Specification

    “Passive House window” is one of the most abused phrases in the industry. Any triple-glazed unit can be called one in a brochure. The Passive House Institute (PHI) certification is the only way to know a window actually performs. Here is what it takes.

    What PHI certification verifies

    PHI does not certify a brand; it certifies a specific window component — frame, glazing and spacer as a system — against measured data. To earn the label, the unit must be submitted with independent test results for thermal transmittance, solar gain and installation context.

    The numbers that matter

    • Uw (whole-window U-value): certified GLOBHAUS PH units reach as low as 1.00 W/(m²K).
    • Glazing U-value (Ug): typically 0.5–0.7 W/(m²K) with argon-filled triple glazing.
    • Solar heat gain (g-value): balanced so winter gain offsets heating without summer overheating.
    • Spacer: warm-edge (not aluminium) to kill the edge condensation bridge.

    Why it protects your project

    A certified window carries a documented, comparable number. When an architect specifies “PHI-certified, Uw ≤ 1.0”, there is no ambiguity and no supplier can quietly swap in a weaker unit. For public tenders and green-building loans, the certificate is often mandatory.

    For importers, a PHI certificate is also a sales weapon: it is the fastest way to prove your window is not greenwashed.

    Beyond the window: installation

    PHI performance assumes correct installation with continuous airtight and insulated junctions. We supply detailed installation memos and, for qualified projects, remote support so the certified value is not lost on site.

    What to ask any supplier

    Request the PHI component certificate number and the corresponding test report. If they only show a “Passive House compatible” badge without a certificate ID, treat it as marketing.

    What Passive House certification actually requires

    A Passive House Institute (PHI) certified component is tested as a whole window — frame, glazing and installation detail together — and must meet a defined energy performance threshold at the quoted size. The certificate covers the specific product configuration, not a brand in general, so a different glazing build-up or frame size needs its own evidence. In practice this means triple low-emissivity glazing, a thermally optimised frame, warm edge spacers and verified airtightness at the junction. The design U-value target and the certification path are confirmed per project with the energy consultant and the certifier, because climate and mounting position change the acceptable numbers.

    Detailing that decides pass or fail

    Most failures are at the connection, not the product. The window must sit within the insulation layer (typically a vapour-open, rain-tight wrap) with a continuous airtight membrane taped to the frame, and the reveal insulated so there is no cold bridge to the room. Internal reveals should stay warm enough to avoid condensation, which is why the installation depth and the insulation strategy matter as much as the frame. Specify the installation concept on the drawing, not just the window, and have the same supplier confirm the junction detail. Any quoted Uw or airtightness value is taken from the certified configuration and the project's confirmed mounting.

    When to specify and when not to

    Full PHI certification is worth it when the building is pursuing Passive House certification or a near-zero target and the client needs the documented proof for finance or code. For a standard renovation, a non-certified triple-glazed uPVC or aluminium-clad unit at a similar U-value often delivers nearly the same comfort at lower cost, provided the installation detail is still done properly. Certify when the proof is required; otherwise buy the performance and spend the saving on the airtightness detail, which is where the comfort is actually won. Confirm the route with the project's energy advisor before fixing the specification.

    Quick takeaways for specifiers

    Full Passive House certification is worth it when the building needs the documented proof for finance, code or its own certification pathway — and not merely as a marketing label. For a standard renovation, a non-certified triple-glazed unit at a similar U-value often delivers nearly the same comfort at lower cost, provided the installation detail is still done properly. That detail is where the comfort is actually won: the window sat within the insulation layer, a continuous airtight membrane taped to the frame, and the reveal insulated so no cold bridge reaches the room. Spend any budget saved on the standard window by investing in that junction, and confirm the mounting concept on the drawing rather than assuming the product alone will perform.
  • Tilt-Turn vs Casement Windows: Which European System Fits Your Project

    Tilt-Turn vs Casement Windows: Which European System Fits Your Project

    Tilt-Turn vs Casement Windows: Which European System Fits Your Project

    GLOBHAUS Engineering Team · 7 min read · 2026-10-20

    Tilt-Turn vs Casement Windows: Which European System Fits Your Project

    Walk through almost any new build in Germany, Austria or Poland and you will see the same window: a tilt-turn. In North America and parts of the UK, the casement still rules. Both open, both ventilate — but under the surface they solve different problems. This guide breaks down the trade-offs so specifiers and importers can choose with confidence.

    How the two operate

    A casement window is hinged on one side and swings outward like a door, usually operated by a crank. A tilt-turn window uses a single handle in three positions: turn it 90° to swing the sash fully inward (for cleaning and egress); turn it 180° to tilt the top inward at the bottom (secure micro-ventilation); or leave it closed and locked.

    That dual action is the whole story. The tilt position lets you leave a window “open” during rain or at night without a security or weather risk — something a casement cannot do.

    Airtightness and energy

    Because tilt-turn sashes seal on all four sides with continuous gaskets, they achieve dramatically lower air-leakage rates than outward casements, which rely on a single compression seal on the hinge side. For Passive House and near-Passive projects, this difference is decisive.

    • Tilt-turn typical air permeability: Class 4 (best band) under EN 12207.
    • Casement: often Class 3–4 depending on hardware and frame quality.
    • Lower leakage means lower heating bills and fewer cold drafts.

    Security and cleaning

    With the sash swung inward, a tilt-turn can be cleaned from inside the room — a major advantage in multi-storey buildings with no exterior access. Casements require exterior access or professional cleaning.

    Security is also stronger: tilt-turn hardware typically engages multiple locking points around the frame, and the tilt position cannot be forced from outside.

    When to specify each

    Choose tilt-turn for residential, low-energy, and multi-storey projects where airtightness, security and indoor cleaning matter. Choose casement where budget is tight, where outward swing is acceptable, or for small aperture vents and storm-prone coastal sites where inward swing is preferred.

    GLOBHAUS builds both, but the UPVC tilt-turn platform is our default recommendation for European-climate imports because it pairs best-in-class airtightness with a 40% cost advantage over aluminium.

    Bottom line for importers

    If you are serving the European or Middle-Eastern market, stock and promote tilt-turn first. Reserve casement for price-sensitive or region-specific requests. Either way, demand documented EN test reports — air, water, wind — before you commit to a container.

    How the two openings behave

    A turn-only casement swings the sash fully into the room on side hinges; a tilt-turn adds a second gear position that cracks the top of the sash inward for secure ventilation. The tilt mode is the日常 difference most users notice: it gives weather-protected airflow with the room unoccupied and the lock still engaged. Casement gives the widest clear opening for cleaning and egress. Both seal well when closed; the choice is about ventilation style and how the opening is used day to day rather than about structural strength, which is comparable for the same profile and glazing.

    Ventilation, cleaning and security

    Tilt-turn suits bedrooms, kitchens and any room left empty for hours, because the tilted position cannot be climbed through and still drafts gently. Casement suits spots where you want the whole pane open — balconies, French-door adjacencies, cleaning access. For cleaning, tilt-turn lets the sash reverse to clean the outside from indoors on most sizes; casement needs the sash to swing clear, which needs interior space. Security is equivalent with multi-point locking; the tilt position is the more child-safe default. Which hardware grade and locking points apply is set per project against the opening size and the required standard.

    Specifying by room

    A simple rule of thumb: specify tilt-turn for the majority of living and sleeping spaces where background ventilation matters, and reserve turn-only casement for service areas or where a fully open sash is the priority. On a single elevation, mixing the two is fine visually if the handle height and frame colour are coordinated. Confirm the hand (left or right turn) and the tilt direction on the schedule, because a reversed unit is annoying to live with even if it functions. Keep the specification performance-led — same U-value and acoustic target — and let the opening type follow the room's use.

    Quick takeaways for specifiers

    Default to tilt-turn for the rooms where background ventilation matters — bedrooms, kitchens and any space left empty for hours — because the tilted position drafts gently yet stays locked and cannot be climbed through. Reserve turn-only casement for service areas or spots where a fully open sash is the priority, such as balcony adjacencies and cleaning access. On a single elevation the two read as one system only if handle height and frame colour are coordinated, so confirm the hand and tilt direction on the schedule to avoid a reversed unit that is annoying to live with. Keep the specification performance-led — the same Uw and acoustic target — and let the opening type follow the room's actual use rather than habit.
  • U-Value, SHGC, NFRC and CE: Reading Window Performance Numbers

    U-Value, SHGC, NFRC and CE: Reading Window Performance Numbers

    The ratings that appear on every glazing schedule, what each one actually measures, and the two figures that matter most per climate.

    U-value

    U-value measures the rate of heat transfer through the whole assembly — frame, spacer and glass — expressed in W/(m²K) or, in North America, as a U-factor in Btu/(h·ft²·°F). Lower is better. The important discipline is to compare like with like: a centre-of-glass U-value is always more flattering than the whole-window figure, and quoting the former is the oldest trick in the specification game.

    SHGC

    Solar heat gain coefficient is the fraction of incident solar radiation that ends up indoors. In cooling-dominated climates a low SHGC is the priority. In heating-dominated climates a higher SHGC contributes useful free heat on south elevations. This is why the ‘best’ window for Toronto is not the best window for Jeddah, even at identical U-values.

    NFRC and CE

    NFRC certification is the North American labelling system; the CE mark under EN 14351-1 is the European route, with declared values for thermal transmittance, air permeability, water tightness and wind resistance. Neither is inherently stricter — they measure differently and are not interchangeable. If a project spans both markets, obtain both declarations from the fabricator rather than converting one into the other.

    Air and water tightness

    Air permeability and water tightness are separate declared classes and, in practice, the cause of most site complaints. A window with excellent thermal numbers and a poor air-sealing class will still feel draughty. Read those two lines on the declaration of performance as carefully as the U-value.

    Acoustics

    Sound reduction is quoted in dB, most often as Rw (or STC in North America). Laminated glass and asymmetric pane thickness outperform symmetric double glazing of the same overall thickness. For sites near highways, railways or flight paths, specify the acoustic figure independently of the thermal one — they do not move together.

    The three numbers that matter

    U-value (Uw for the whole window) measures heat loss — lower is better. SHGC (solar heat gain coefficient) measures how much sun energy passes through — higher means more free heat, which is good in cold climates and a liability in hot ones. A third figure, the air leakage rate, shows how tight the unit is. These are not preferences; they are measured properties, and the right balance depends on where the building sits. A north-facing opening in a heating climate wants low Uw and higher SHGC; a west façade in a hot climate wants low Uw and low SHGC. The exact target values are set per project with the energy model and the local code.

    How the numbers are produced

    In Europe the declared values follow EN and are often shown as CE-labelled performance; in North America NFRC provides a comparable labelled U-factor and SHGC. The important point is that the figure must refer to the whole window (frame plus glazing, at the quoted size), not the centre-of-glass alone, because the frame is where real windows lose most heat. Ask for the certified configuration behind any number, and make sure the glazing build-up quoted is the one tested. Any Uw, SHGC or acoustic rating used in a quote is taken from the certified product file for that exact specification.

    Using the numbers without being misled

    Never compare a centre-of-glass U-value against a whole-window Uw — the frame alone can add 30–50% to the loss. Watch for SHGC being quoted without saying which climate it helps; a high SHGC is only 'good' in a heating-dominated site. And remember that a lower Uw usually costs more and can reduce light transmittance, so optimise to the project's actual need rather than chasing the smallest number. Specify the performance band, ask for the certified evidence, and let the factory propose the glazing build-up that meets it at the right cost.

    Quick takeaways for specifiers

    Read the three numbers together, never in isolation. Uw measures whole-window heat loss and should be low; SHGC measures solar heat gain and is good high in a heating climate but a liability in a hot one; the air-leakage rate shows how tight the unit is. Always compare whole-window figures, because a centre-of-glass U-value ignores the frame where real windows lose most heat, and ask for the certified configuration behind any number you are quoted. Balance Uw and SHGC to the building's climate rather than chasing the smallest figure, since an aggressive low-SHGC glazing can darken a view unnecessarily. Specify the performance band, request the certified evidence, and let the factory propose the build-up that meets it.
  • Garage Door Insulation and Wind Load: What North American Projects Require

    Garage Door Insulation and Wind Load: What North American Projects Require

    Why a door that looks right in a showroom can fail inspection on a wind-rated opening, and the three numbers to confirm before you order.

    Wind load is a code item, not a preference

    Most coastal and many inland US and Canadian jurisdictions require garage doors on wind-rated openings to carry a design pressure rating, and increasingly require evidence of compliance rather than a manufacturer’s statement. Confirm the required design pressure (positive and negative) for the specific opening before selecting the door — exposure category, building height and opening location all change the number.

    Insulation: what the R-value is actually telling you

    Sectional doors are usually quoted with a polyurethane or polystyrene core. Polyurethane foamed in place gives a higher R-value per millimetre and adds measurable panel stiffness; polystyrene is cheaper but contributes less structurally. If the garage is conditioned, or a workshop, the core choice is worth specifying — if it is a detached unconditioned garage, spend the budget on the wind package instead.

    Reinforcement and track

    Wind-rated doors need struts, heavier gauge end and centre hinges, and correctly rated track and brackets. A door panel that passes a pressure test but is hung on standard track will still fail. Order the wind package as a system, and make sure the installation crew uses the specified fasteners into the specified substrate.

    Cycle life and hardware

    On a main residence the door may cycle four to six times a day, every day, for twenty years. Specify spring cycle rating accordingly — 10,000 cycles is a light-duty figure, 25,000 and above is realistic for a family home. Quiet operation comes from the roller and hinge specification, not from the opener.

    Documentation to request

    Ask for the design pressure rating with the test report reference, the R-value calculation method, the spring cycle rating, and the hardware gauge. If a supplier cannot produce the first of these in writing, the door is not wind-rated regardless of what the brochure implies.

    Insulation that actually works

    A garage door's thermal performance comes from the panel core — typically a rigid foam sandwich — not the skin. The meaningful figure is the panel's published R-value or U-value, and the weak points are the joints between sections and the perimeter seal, where most air leaks occur. For an attached garage that shares a wall with the house, insulate and seal the door as if it were an external wall; for a detached garage, a basic panel is usually enough. Weather-stripping at the base and sides, plus a well-fitted header seal, matters as much as the core. The specific insulation value and panel make are confirmed per project against the required rating.

    Wind load and reinforcement

    Large door panels are sails: in exposed or high-wind sites they must resist the design wind pressure without bowing or losing the track. The rating depends on door area, local wind zone and how the opening is sheltered, so it is a calculated requirement, not a single grade. Reinforced stiles, a heavier gauge skin and properly anchored tracks are how a door earns a higher rating; a flimsy track is the usual failure point. Confirm the design wind load with the structural information for the site, and specify the door to that value rather than accepting a generic 'storm-rated' label that may not match the location.

    Specifying for the site

    Give the supplier the door size, the local wind zone (or the project's structural wind load), whether the garage is attached, and the target insulation. From that they can propose the panel thickness, reinforcement and seal package. Avoid picking a door by colour or price alone and assuming it will cope — an under-specified panel in a windy site is a recurring service call. Ask for the rated values in writing and check the track and anchor specification, because that is what actually carries the load. Any performance figure quoted is taken from the certified configuration for that door size and site class.

    Quick takeaways for specifiers

    A garage door's performance lives in its details more than its brochure. The insulated sandwich panel carries the R-value or U-value, but the joints between sections and the perimeter seal are where most air leaks occur, so weather-stripping and a fitted header seal matter as much as the core. For an attached garage sharing a wall with the house, treat and seal the door as an external wall; for a detached one, a basic panel is usually enough. Rate the door to the site's calculated wind load rather than a generic storm label, and check the track and anchor specification, because that is what actually carries the load. Any quoted performance figure comes from the certified configuration for that door size and site class, confirmed before the order is fixed.
  • Specifying Windows for Gulf Climates: Heat, UV and Sand

    Specifying Windows for Gulf Climates: Heat, UV and Sand

    What changes when a window system rated for Central Europe is installed in Jeddah or Riyadh — and the four specification decisions that matter most.

    The load case is different

    A window specified for a temperate climate is designed around heating retention. In the Gulf the dominant load is solar gain — peak ambient temperatures above 45 °C combined with direct irradiance that can push the outer pane past 70 °C. The result is a thermal gradient across the insulated glass unit that temperate specifications rarely account for, and it is the usual root cause of seal failure and spacer creep on imported systems.

    Glazing does most of the work

    Specify a double-silver or triple-silver Low-E coating on surface 2, with a solar heat gain coefficient at or below 0.25 for large west and south elevations. Argon fill is worth the small premium; warm-edge spacers matter more than most specifiers expect, because the spacer is the thermal bridge that drives condensation at the glass edge.

    Frame colour and thermal movement

    Dark anodised or powder-coated frames look right on contemporary Gulf villas but absorb far more radiation than white frames. On large spans the resulting expansion is real — confirm the system’s expansion allowance with the fabricator, and do not reduce clearance to tighten a sightline.

    Sand, salt and hardware

    Fine abrasive dust plus coastal humidity is hard on moving parts. Specify stainless or appropriately coated hardware, multi-point locking with covered keeps, and gaskets that are rated for continuous compression at temperature. Inland desert projects and coastal projects are not the same specification, even inside the same country.

    What to ask your fabricator

    Ask for the U-value and SHGC of the complete unit, not the centre-of-glass figure. Ask which spacer system is used. Ask for the hardware coating specification in writing. Ask whether the profile has been cycled at temperature — and ask for the test report, not a marketing claim.

    Heat, UV and sand are the real loads

    In Gulf and similar hot-arid climates the window is fighting solar gain and UV far more than cold. The priority is a low SHGC with high visible light, a low Uw to cut conductive gain, and a frame and gasket package that survives intense UV without chalking or hardening. Sand and dust demand tighter seals and easy-clean surfaces, and high humidity at the coast demands corrosion-rated hardware. Colour matters too: dark frames absorb heat, so lighter or specially coated finishes stay cooler. The exact performance band is set per project with the energy model and the local authority requirements.

    Glazing and coating strategy

    A solar-control low-emissivity coating on the right glass surface does most of the work; pair it with a wider air gap or inert fill to push the Uw down without darkening the view. Consider a higher performance interlayer where safety or acoustic separation is needed, and specify the glazing build-up as a tested unit rather than mixing loose components. External shading — fins, screens or recessed reveals — reduces gain further and protects the frame from direct sun. Any Uw, SHGC or acoustic value used in the specification is taken from the certified glazing configuration for that project.

    Detailing for longevity

    Specify hardware and fixings to the coastal corrosion class, and confirm the drainage path stays clear of sand build-up so the frame does not sit in moisture. Gaskets should be UV-stable grades; cheaper rubber hardens and leaks within a couple of summers. For large façades, phase the commissioning so the first installed bays are checked through a full summer before the rest are released. Keep the specification performance-led — same target Uw and SHGC — and let the factory propose the frame finish and glazing that meet it for the site's exposure class. Request the certified evidence for the exact build-up before the order is fixed.

    Quick takeaways for specifiers

    In hot-arid Gulf conditions the window fights solar gain and UV far more than cold, so lead with a low SHGC and high visible light, a low Uw, and a frame and gasket package built to survive intense sun without chalking or hardening. Sand and dust demand tighter seals and easy-clean surfaces, and coastal humidity demands corrosion-rated hardware. A solar-control low-emissivity coating on the correct glass surface does most of the work; pair it with wider gaps or inert fill to push Uw down without darkening the view, and add external shading to cut gain before it reaches the glass. Specify performance first, let the factory propose the finish and glazing, and request the certified evidence for the exact build-up.
  • Zip High-Speed Door

    Zip High-Speed Door

    Zip High-Speed Door. Zip-sealed curtain with near-zero leakage for clean and cold rooms.

    Zip High-Speed Door — GLOBHAUS
    Near-zero leakage · Dust control · Cold containment

    Zip High-Speed Door

    Zip-sealed curtain with near-zero leakage for clean and cold rooms.

    Overview

    Zip-sealed curtain with near-zero leakage for clean and cold rooms. The GH-HS400 is built on the GLOBHAUS integrated production base and specified for Clean rooms, cold storage, food production. Zip seal closes the air path. Protects clean-room classification.

    Technical specification

    CurtainZip-sealed PVC
    SealNear-zero air leakage
    FunctionDust and cold containment
    DriveHigh-speed motor
    CertificationCE · fire-rating certificate per compartment
    Warranty2 years on operator, 5 years on curtain
    MOQ1 × 20 ft container
    Lead time25–35 days
    ServiceOEM / ODM custom, project engineering

    Why specify this unit

    ✓
    Near-zero leakage: Zip seal closes the air path.
    ✓
    Dust control: Protects clean-room classification.
    ✓
    Cold containment: Stops temperature bleed between zones.
    ✓
    Food safe: Specified for hygiene-controlled areas.
    ✓
    One source factory: Built, tested and packed at the GLOBHAUS integrated base in Foshan — no trading margin.
    ✓
    Made to the opening: Sizes, finishes, glazing and operation specified per project, not sold off a size chart.
    ✓
    Export ready: Foam-framed, corner-guarded and container-loaded with full documentation.
    ✓
    OEM / ODM: Private label, custom profiles and project documentation supported.

    Gallery

    Zip High-Speed Door — GLOBHAUS Zip High-Speed Door — GLOBHAUS Zip High-Speed Door — GLOBHAUS

    Talk to the factory

    MOQ, lead time, glazing and hardware — quotations within 24 hours.

    Request a Quote
  • WPC Interior Door

    WPC Interior Door

    WPC Interior Door. Waterproof, moisture-proof WPC door for humid and high-temperature interiors.

    WPC Interior Door — GLOBHAUS
    Waterproof · Durable and green · Project volume

    WPC Interior Door

    Waterproof, moisture-proof WPC door for humid and high-temperature interiors.

    Overview

    Waterproof, moisture-proof WPC door for humid and high-temperature interiors. The GH-WP100 is built on the GLOBHAUS integrated production base and specified for Middle East humid and high-temperature interiors, residential. Does not swell in humid or wet-room conditions. Long service life from a recycled composite.

    Technical specification

    MaterialWood-plastic composite
    PropertyWaterproof and moisture-proof
    DurabilityLong service life, environmentally friendly
    CapacityHigh-volume project supply
    CertificationCE · zero formaldehyde (E0)
    Warranty5 years
    MOQ1 × 20 ft container
    Lead time25–35 days
    ServiceOEM / ODM custom, project engineering

    Why specify this unit

    ✓
    Waterproof: Does not swell in humid or wet-room conditions.
    ✓
    Durable and green: Long service life from a recycled composite.
    ✓
    Project volume: Supplied at development scale.
    ✓
    Certified: Produced under recognised quality and housing approvals.
    ✓
    One source factory: Built, tested and packed at the GLOBHAUS integrated base in Foshan — no trading margin.
    ✓
    Made to the opening: Sizes, finishes, glazing and operation specified per project, not sold off a size chart.
    ✓
    Export ready: Foam-framed, corner-guarded and container-loaded with full documentation.
    ✓
    OEM / ODM: Private label, custom profiles and project documentation supported.

    Gallery

    WPC Interior Door — GLOBHAUS WPC Interior Door — GLOBHAUS WPC Interior Door — GLOBHAUS

    Talk to the factory

    MOQ, lead time, glazing and hardware — quotations within 24 hours.

    Request a Quote
  • Aluminium Wind-Resistant Folding Window

    Aluminium Wind-Resistant Folding Window

    Aluminium Wind-Resistant Folding Window. Folding aluminium window engineered for high-rise wind loads.

    Aluminium Wind-Resistant Folding Window — GLOBHAUS
    High-rise rated · Outdoor durable · Folds away

    Aluminium Wind-Resistant Folding Window

    Folding aluminium window engineered for high-rise wind loads.

    Overview

    Folding aluminium window engineered for high-rise wind loads. The GH-WF600 is built on the GLOBHAUS integrated production base and specified for High-rise residential, coastal areas. Engineered for wind load at height. Corrosion-resistant aluminium and hardware.

    Technical specification

    StructureAluminium folding sash
    WindEngineered for high-level wind load
    CorrosionOutdoor rust-resistant finish
    OperationFolding, manual
    CertificationCE · ISO 9001
    Warranty10 years on profile
    MOQ1 × 20 ft container
    Lead time30–40 days
    ServiceOEM / ODM custom, project engineering

    Why specify this unit

    ✓
    High-rise rated: Engineered for wind load at height.
    ✓
    Outdoor durable: Corrosion-resistant aluminium and hardware.
    ✓
    Folds away: Sashes stack to open the elevation.
    ✓
    Balcony use: Common on high-level terraces.
    ✓
    One source factory: Built, tested and packed at the GLOBHAUS integrated base in Foshan — no trading margin.
    ✓
    Made to the opening: Sizes, finishes, glazing and operation specified per project, not sold off a size chart.
    ✓
    Export ready: Foam-framed, corner-guarded and container-loaded with full documentation.
    ✓
    OEM / ODM: Private label, custom profiles and project documentation supported.

    Gallery

    Aluminium Wind-Resistant Folding Window — GLOBHAUS Aluminium Wind-Resistant Folding Window — GLOBHAUS Aluminium Wind-Resistant Folding Window — GLOBHAUS

    Talk to the factory

    MOQ, lead time, glazing and hardware — quotations within 24 hours.

    Request a Quote
  • Valencia Series System Window

    Valencia Series System Window

    Valencia Series System Window. The flagship German system window — 3.0 mm alloy-resin, six chambers, multi-point locking.

    Valencia Series System Window — GLOBHAUS
    German system geometry · 3.0 mm wall thickness · Six-chamber seal

    Valencia Series System Window

    The flagship German system window — 3.0 mm alloy-resin, six chambers, multi-point locking.

    Overview

    The flagship German system window — 3.0 mm alloy-resin, six chambers, multi-point locking. The GH-GS100 is built on the GLOBHAUS integrated production base and specified for High-end residential, villas. Profile and hardware developed on the German system platform. Heavy-wall alloy-resin for rigidity and fixings.

    Technical specification

    ProfileAlloy-resin, 3.0 mm wall thickness
    ChambersSix-chamber multi-seal geometry
    HardwareGerman multi-point locking
    FinishGerman simulated wood-grain lamination
    CertificationCE · NFRC (PHI on project)
    Warranty10 years on profile
    MOQ1 × 20 ft container
    Lead time30–40 days
    ServiceOEM / ODM custom, project engineering

    Why specify this unit

    ✓
    German system geometry: Profile and hardware developed on the German system platform.
    ✓
    3.0 mm wall thickness: Heavy-wall alloy-resin for rigidity and fixings.
    ✓
    Six-chamber seal: Multi-chamber profile with staged sealing.
    ✓
    Wood-grain interior: German lamination gives a timber look without timber upkeep.
    ✓
    One source factory: Built, tested and packed at the GLOBHAUS integrated base in Foshan — no trading margin.
    ✓
    Made to the opening: Sizes, finishes, glazing and operation specified per project, not sold off a size chart.
    ✓
    Export ready: Foam-framed, corner-guarded and container-loaded with full documentation.
    ✓
    OEM / ODM: Private label, custom profiles and project documentation supported.

    Gallery

    Valencia Series System Window — GLOBHAUS Valencia Series System Window — GLOBHAUS Valencia Series System Window — GLOBHAUS

    Talk to the factory

    MOQ, lead time, glazing and hardware — quotations within 24 hours.

    Request a Quote

    Frequently asked questions

    What is the minimum order quantity for Valencia Series System Window?

    The MOQ is 1 × 20 ft container. Mixed configurations and sizes can be loaded in the same container, so a project schedule does not need to reach container volume for a single SKU.

    How long does production take?

    Standard lead time is 30–40 days after drawing and glass build-up approval. Packing, documentation and container loading are included in that window.

    Which glazing options can be specified?

    The specification for this unit is: double or triple insulated, Low-E, laminated or tempered glass. The final build-up is confirmed against the project’s thermal, acoustic and safety requirements.

    Can dimensions, finishes and hardware be customised?

    Yes — OEM / ODM custom, project engineering. The platform is multi-chamber lead-free PVC-U or aluminium profile systems, and sizes, colour, glass and hardware grade are set per project rather than sold from a fixed size chart.

    Which certification documents are supplied?

    CE · NFRC (PHI on project). State the destination market and the required test reports at RFQ stage so the correct documentation is quoted with the order.